Mainly used for tissue resection, transection and anastomosis in endoscopic surgery of abdominal surgery, gynecology, pediatrics and thoracic surgery.
Mainly used for tissue resection, transection and anastomosis in endoscopic surgery of abdominal surgery, gynecology, pediatrics and thoracic surgery.
【Scope of application】
It is suitable for closing stumps or incisions in laparoscopic gastrointestinal reconstruction and organ resection surgeries.
【Product performance】
The main technical indicators of Electronic endoscopic cutting staplers include easy replacement of stapler
components, reliable positioning, and the stapler has an empty staple bin safety protection device and maintains its reliability, and the product should be sterile.
【Main structural components】
1. Product classification
1. 1Disposableelectronic endoscopic cutting staplers and reload consists of two parts: body and components. The body of the device is composed of a nail bin seat (nail box base), a nail base, a joint head, a knob, a conversion button, a reset button, a battery pack, a handle, a closing handle, and a firing button. The assembly is composed of a nail bin and an anastomotic staple.
The same electric endoscopic stapler can use multiple components in one operation.
Both Disposable electronic endoscopic cutting staplers and reload are packaged independently.
Products should be sterile after ethylene oxide sterilization.
Table 1 Type A electric stapler body model specifications and basic dimensions Unit: mm
|
Model specifications |
Boom length (L3) |
Allowance |
Model specifications |
Boom length (L3) |
Allowance |
|
GCEECSA190- 30P |
190 |
±15 |
GCEECSA190- 30Y |
190 |
±15 |
|
GCEECSA190- 45P |
190 |
GCEECSA190- 45Y |
190 |
||
|
GCEECSA190- 60F |
190 |
GCEECSA190- 60Y |
190 |
||
|
GCEECSA250- 30P |
250 |
GCEECSA250- 30Y |
250 |
||
|
GCEECSA250- 45P |
250 |
GCEECSA250- 45Y |
250 |
||
|
GCEECSA250- 60P |
250 |
GCEECSA250- 60Y |
250 |
||
|
GCEECSA350- 30P |
350 |
GCEECSA350- 30Y |
350 |
||
|
GCEECSA350- 45P |
350 |
GCEECSA350- 45Y |
350 |
||
|
GCEECSA350- 60P |
350 |
GCEECSA350- 60Y |
350 |
Table 2 Basic dimensions of nail bin components for A-type body Unit: mm
|
Nail bin model specifications |
Anastomosis length (L2) |
Allowance |
Staple height (H) |
Allowance |
|
GCEECRA- 30M |
33.0 |
±2.0 |
2.0 |
±0.2 |
|
GCEECRA- 30W |
33.0 |
2.5 |
||
|
GCEECRA- 30B |
33.0 |
3.5 |
||
|
GCEECRA- 30G |
33.0 |
3.8 |
||
|
GCEECRA- 30H |
33.0 |
4.1 |
||
|
GCEECRA-30T |
33.0 |
4.4 |
|
GCEECRA- 45M |
48.0 |
±2.0 |
2.0 |
±0.2 |
|
GCEECRA- 45W |
48.0 |
2.5 |
||
|
GCEECRA- 45B |
48.0 |
3.5 |
||
|
GCEECRA- 45G |
48.0 |
3.8 |
||
|
GCEECRA- 45H |
48.0 |
4.1 |
|
Nail bin model specifications |
Anastomosis length (L2) |
Allowance |
Staple height (H) |
Allowance |
|
GCEECRA- 45T |
48.0 |
4.4 |
|
|
|
GCEECRA- 60M |
60.0 |
±2.0 |
2.0 |
±0.2 |
|
GCEECRA- 60W |
60.0 |
2.5 |
||
|
GCEECRA- 60B |
60.0 |
3.5 |
||
|
GCEECRA- 60G |
60.0 |
3.8 |
||
|
GCEECRA- 60H |
60.0 |
4.1 |
||
|
GCEECRA- 60T |
60.0 |
4.4 |
||
|
GCEECRB- 30M |
33.0 |
±2.0 |
2.0 |
±0.2 |
|
GCEECRB- 30W |
33.0 |
2.5 |
||
|
GCEECRB- 30B |
33.0 |
3.5 |
||
|
GCEECRB- 30G |
33.0 |
3.8 |
||
|
GCEECRB- 30H |
33.0 |
4.1 |
||
|
GCEECRB-30T |
33.0 |
4.4 |
||
|
GCEECRB- 45M |
48.0 |
±2.0 |
2.0 |
±0.2 |
|
GCEECRB- 45W |
48.0 |
2.5 |
||
|
GCEECRB- 45B |
48.0 |
3.5 |
||
|
GCEECRB- 45G |
48.0 |
3.8 |
||
|
GCEECRB- 45H |
48.0 |
4.1 |
||
|
GCEECRB-45T |
48.0 |
4.4 |
||
|
GCEECRB- 60M |
60.0 |
±2.0 |
2.0 |
±0.2 |
|
GCEECRB- 60W |
60.0 |
2.5 |
||
|
GCEECRB- 60B |
60.0 |
3.5 |
||
|
GCEECRB- 60G |
60.0 |
3.8 |
||
|
GCEECRB- 60H |
60.0 |
4.1 |
||
|
GCEECRB-60T |
60.0 |
4.4 |
Factory Area (m² )
Export Countries